We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. This error informs you there is something wrong while you reset the unit. Your Navien Recirculation Pump will make a humming noise like a refrigerator if you dont bleed the air out of the recirculation system. Weve tried to include every concern you might have regarding turning off the water recirculating pump. If we take that the average price of water is $0.18/gallon (according to Statistas 2019 study), heres how much you can save on water with a recirculation pump: Water Savings = 2,920 gallons/year * $0.18/gallon = $525.60/year. Remove the front cover of the water heater. However, this is only a temporary fix. (42-167 Amps), How Much Propane Does A Tankless Water Heater Use? Below are different Navien water heater error codes and their solutions; Navien error code 003 how to fix indicates that there is an ignition failure in your unit. Also, check if the electrical cord is grounded correctly or not. Confirm the thermistor and wiring is in good condition. Create a chart to regulate hot water usage. However, that shouldnt happen if you have turned the pump off. It is affordable and can easily fix your problem. Press the + (Up) or (Down) buttons until the desired temperature appears on display. Making statements based on opinion; back them up with references or personal experience. The exhaust is overheating. Fits These Models First, place a thick rubber between the pump and anything it will be mounted on. Check this too: Electric RV Water Heater How to & Troubleshooting Guide "The recirculating pump costs about the same as operating a 25-watt light bulb," says Umberto Griccino, a commercial plumber and HouseGrail consultant. Make sure to follow our instructions properly for the right application. here are some problems that you may have to deal with in the future or have experienced already primarily found in older Navien heater models; Though not a common occurrence, it is still essential to know how to identify these issues. From the valve, try to loosen up the cap to remove air from the system. If enabled you would find that your hot water is ready to go almost anytime you need it, without a long wait. My pipes arent big enough 2. I was under impression that with the recirculation pump this wouldnt be an issue (the wait time) and the fact that the water is just warm otherwise feels wrong. Is it possible to create a concave light? Here are some of the leading causes of cold water production; Which means there isnt enough time for the water to heat up. A while ago we had a plumber/friend install a Navien tankless water heater. It clips on the side of the PCB board without screws and then you connect a ribbon cable to the PCB. This can be determined based on the following factors: The average water usage for different hot water uses are as follows; Check this too: Insinkerator Hot Water Dispenser How-to & Troubleshooting Guide. Cookie Notice Additionally, you can install a 5-micron filter in the water inlet right before the heater to remove impurities from the water. If your system displays this code, you need to confirm the water pressure is within good ranges. However, I have envious of those who have the NPE with the hot button and wifi link. The cold water pipe coming from the wall goes into the domestic water inlet on the tankless heater, as it should. NEC 310.16 Table: Copper And Aluminum Wire Ampacity Chart, NEC 310.12 Table: Wire Sizes For 100-400 Amp Services (83% Rule), kWh To Therms Calculator + Conversion Chart (1 kWh = 0.03412 Therms), MMBTU To Therms Calculator + Chart (1 MMBTU = 10 Therms), Therms To MMBTU Calculator + Chart (1 Therm = 1/10 MMBTU), AWG To Circular Mils Chart (For 4/0 AWG To 20 AWG). my understanding of the Navien with internal recirc pump is that they work with either an external dedicated return pipe or an internal bypass loop located within the water heater cabinet. Grundfos water recirculation pump may troubleshoot sometimes. Then descale a flush the heater following the steps listed below. Then what are we waiting for? I connected the Hot Button control board to the main PCB per the instructions. What Is the Difference Between 'Man' And 'Son of Man' in Num 23:19? New build - tankless hot water heater - recirculation pump needed? - Houzz An open or short thermistor can be the root cause of this problem. Is this incorrectly installed? Turn off the recirculation when the house is not occupied, in order to save even more energy. 08. 3. What am I doing wrong here in the PlotLegends specification? Correcting Navien Tankless Hot Water Heater Installation, We've added a "Necessary cookies only" option to the cookie consent popup, Tankless water heater - not consistent hot water output, Plumbing Manifold Use With a Tankless Hot Water Heater, No hot water if hot water recirculator pump is shut off, warm water only when we replaced the hot water heater with a tankless heater. You can install it yourself (DIY circulation pump installation) or call a professional; more on that in the part about how much do hot water recirculating pumps cost. I broke down all the possible reasons that cause your Navien Recirculation Pump to produce a humming noise. How To Turn On A Navien Tankless Water Heater | GardeningLeave House was built in late 1990s and is 2 story, built on a slab foundation. they have an accessory called the HotButton (PZZZ-00046). Is this a common drawback with the under-sink crossover valves, for the heater to turn on when a cold water faucet is turn on? What video game is Charlie playing in Poker Face S01E07? It shows that the water adjustment valve is not operating properly. The total amount of water needed is 2 gallons + 1.5 gallons + (3 gallons * length of shower). Navien NPE-240 A Recirculation Linewww.amazon.com/shop/miheatingguyMilwaukee 2131-20 M18 ROCKET Dual Power Tower Lighthttps://amzn.to/3pe2hYHMilwaukee M12 Surge Hydraulic Driver Kit #2551-22https://amzn.to/3n5offbMakita E-01563 Impact XPS 3 Pc. If it does, you could trigger the operation to save money whenever your system detected 'away' or however you've got it programmed. You can turn it off during work hours, over the night, when you go on vacations, and so on. Also, turn off the water heater, and recirculate the pump. I may be able to correct this if I solve the mystery on where the dedicated return line might be. I have alos checked my HeatBox settings to ensure the temp is set high enough for my domestic supply (set to around 120 degrees). Hathaspace Smart True HEPA Air Purifier Reviews, 4+6 Best Whole-House Dehumidifiers (Ducted, Portable), 4 Quietest Dehumidifiers (Best Bedroom Dehumidifiers): 52.1 dB Or Lower, energy-efficient way of getting hot water. Heres the deal on how to get the hot water faster from a water heater: When we turn on any faucet, the hot water needs to travel from the hot water heater to the faucet. This serves two functions: This is also true for tankless water heaters. Then what are we waiting for? There are more options, for example- you can buy a wifi socket. Its a piece of cake to bleed the air out of your Navien recirculation pump. The remote control module sits beside this area (I have it floating but I'll put double stick tape and mount it to the interior soon) and the antenna lead drops through a grommet (conveniently already available at the bottom of the unit near the pcb) to the outside. if your water heater has 4 connections (CW in; HW out; condensate; gas) then the recirculation occurs within the water heater - IMO don't see the benefit in this setup as the water in the HW distribution system doesn't see flow . Connect and share knowledge within a single location that is structured and easy to search. So, saving water is the main reason for calling a recirculation pump eco-friendly. By installing a hot water circulation pump, you will have a hot shower right away. Unplug the power to your Navien water heater. Though we share resources, information, and educational guide on plumbing & DIY projects, the content here is not a substitute for professional guidance. If you'd like to support the site, please allow ads. Turns out, make sure you isolate the recirculation pump from the vibration. Purchasing a timer will also fix the problem. The water heater will not provide hot water instantly. So, keep reading till the end. (State-By-State Chart), How To Convert Therms To kWh? Does anyone know the logic behind how Navien controls their internal recirculation pump when it is circulating with an external loop? Is there a proper earth ground point in this switch box? SEER = (1 EER100% + 42 EER75% + 45 EER50% + 12 EER25%)/100, Total Heat (BTU/hr.) air), Latent Heat (BTU/hr) = 0.69 x CFM x gr. We have some suggestions for you if you want to buy the best wifi sockets. Turn off the device and examine the APSs condition. To remedy the issue, consider increasing the gas supply to the heater. As a result, the stuff will rub against the wall of the pump and produce a hum like a refrigerator when you turn the unit on. Hi Patrick, thats a good insight. . You May Forget to Purge The Recirculation Pump, 03. Many systems turn on and off automatically to keep the water within a specified temperature range. Then re-insert the filter and screw it back in place. Dont hesitate to switch the tees around if you get them backward. The circulation return needs to come from a loop at an end of the hot supply line. What about adding the NaviLink WiFi board and controlling it from your phone anywhere? Some of our partners may process your data as a part of their legitimate business interest without asking for consent. The number of bathrooms, tubs, dishwashers, and washers. Here is the final install. = 4.5 x CFM x h (std. I just hooked up the NR-20DU wired remote control ($80 from Fergusons) and programmed 3 on/off recirculating cycles based on family needs. Next, hook hoses to the valves, then open them to drain the water. My navien furance is producing hot water but not circulating First, you need to consider Things to consider when sizing the busiest usage period or peak time. This time of year, we dont need to have instant hot water circulating so we turned off the pump. This is known as recirculating home pump comfort system (Type #2) and its the most popular way to get hot water quickly. Where did you find that info? I used a razor and carefully pried each side of the RM11 open to reach the programming switch. Navien 240A2 tankless help : r/Plumbing - reddit 2. Putting one recirc line in won't turn a line and branch system into a loop system automatically. We have a standard gas hot water heater with a circulating pump. Parts that will actually be used depend on what kind of hot water recirculation pump you have. To reduce that time significantly (and stop needlessly wasting water), we can install hot water recirculating pump. Tankless Water Heater Wire Size Calculator: What Gauge Wire (AWG)? They are not without upfront costs or disadvantages, but they do offer the luxury of having hot water almost instantaneously and they save you a lot of water. Remove the screw that secures the air intake filter and then remove the filter. It means that there is an issue with the air pressure sensor. First, find the control panel on the front of the unit. Here are the leading causes of strange noises coming from your heater; Hire a professional or installer to repair your heater to avoid damaging the heater and voiding your warranty. Types of water circulation pumps, including tankless water heater recirculation pumps. Do Tankless Water Heaters Needs Recirculation Pumps? You can contact a plumber if necessary. That is a premium service however. Is a Hot Water Recirculating Pump Worth It? 10 Pros and Cons - Your H2Home . So, there is such a thing. Calculator + Chart (Natural Gas), Average Gas Bill For 1-Bedroom Apartment: State-By-State Cost Analysis, Average Electricity Bill For 4 Person Household (Survey Analysis), How Many kWh Per Day Is Normal? The estimated annual operating cost of the Navien tankless water heater, based on the yearly estimated residential use per US Energy Department test criteria, is $191. Yes!!! On top of that, the recirculating pumps also return the cold water in the pipes back to the heater. Let's hop in! Navien NPE-240s with external recirculating pump. - JustAnswer Well tackle the installation and running costs of a circulating pump in full near the end. This made me suspicious that water was coming from the mains. It also increases the gas bill. Brand: Navien. (Cost Calculations), BTU/h To Horsepower Calculator + BTU/h To HP Chart (To 72,000 BTU/h), Horsepower To BTU/Min: Convert HP To BTU Per Minute (Calc + Chart), HP To BTU/hr: Horsepower To BTU For A/C (Calculator + Chart). There are filters that prevent the sediment from entering the water flow. Minimising the environmental effects of my dyson brain. Overusing your recirculating pump also increases your electricity bill. Turning off your water recirculating pump reduces damage. Here is the list of all the parts you need to install a recirculation pump. It worked perfectly. Why Its Important To Turn Off The Water Recirculating Pump? Hot Water Recirculating Pump: What To Know Before You Buy Solar panels, wiring, old TVs and sometimes DIY powerwalls. Locate the power button and press it to turn on the heater. Thats why most homeowners prefer installing the recirculation pump without the extra pipe. How? Ensure all return and supply lines are open and check the 2-way valves direction. There are special tankless water heater recirculation pumps for Navien, Rinnai, and Rheem units; we will cover them all. plumbing - Why is my hot water circulator causing there to be hot water If the problem persists, call a technician to fix the unit. The hot water recirculation pump works by: The very phrase recirculating comes from this pump returning the unused hot water back into the tank. In fact, with a tankless water heater, you face double trouble (thats why youre not getting hot water fast): Because we need to wait longer for hot water in the case of tankless water heaters vs. traditional water heaters, it makes sense to minimize that time in tankless heaters even more. We have to keep the valve on and slowly hot water comes out. Yes, you can turn it off by yourself. I added an additional remote for a total of 3. Full Recirculation Pump System - Going this route adds additional piping to your system, allowing for a "hot water loop" to be created, ensuring the water doesn't end up sitting and going cold in your pipes and instead is recirculated, ready for the next time you turn on the tap. There is some issue with the front panel key. Press question mark to learn the rest of the keyboard shortcuts. Patrick. You mentioned that in the summer months your can turn off the recirculation pump. NPE-A2 Series | Navien You can contact a plumber if necessary. Ask Your Own HVAC Question b55db6.jpeg 6a7761.jpeg ee4ed0.jpeg cc7ba2.jpeg 8ec6a3.jpeg 32aa59.jpeg Hi. W2 Wire Thermostat Wiring (2nd Stage), Thermostat Wire Color Codes For 3-8 Wire Thermostats (Color-By-Color), How Many Therms Of Gas Per Month Is Normal? Using a corrosion-free flow sensor made of stainless steel is a better option. Free returns are available for the shipping address you chose. Some sort of noise out of your Navien recirculation pump is normal. The cold water pipe coming from the wall goes into the domestic water inlet on the tankless heater, as it should. I recently had a 240A2 installed. Is this a common drawback with the under-sink crossover valve? Power Waste Check to see if the warranty is still valid and contact the manufacturer. Turn off the unit and check the valve's wiring and condition. I agree the user manuals are very helpful. Not sure I am understanding. Then, you can change the tank thermistor if needed. When you turn on the shower or a faucet, do you get hot water instantly? Thats why turning off your pump is important when youre not using it. Hope this illustrates well why this might be occurring; its a pretty standard thing. We were advised of this upon installation. To calculate the size of the heater, you will need to add up the amount of water required at a particular time. If any of them are loose or disconnected, your circulator pump won't work. Navien NPE-240 A Recirculation Line - YouTube You need to run white vinegar through the system, to descale the water heater. With the NRCR you can set your own schedule with a remote accessory and tailor the integrated pump to your lifestyle or scheduled needs. This happens when you have a huge heater and lower gas output. Hi Mike, we think about water as hot vs. cold. You certainly dont want that, do you? For example, if you get the tees backward, the recirculation pump will not function properly. Otherwise, turn it off. It provides information about the problem with the fan motor. Can I swap out the mainboard in the NR240A to an NPE240A board to get all that features? Quick summary on costs: Recirculating a pump is certainly useful if you want hot water quickly. Always on checks in every 30 minutes and turns on the heat recirculation if the water is 9 degrees under the water goal temp. To understand this problem what I am talking about, you can watch this video: First off, I recommend you check the primary loop. Close the cold and hot water inlet valves and then drain the water heater. Having a tankless water heater is an energy-efficient way of getting hot water. The plumber said that he tied in both in the master bathroom and the kitchen but Ill crawl under the house to validate this. I think it's 100F. Hi: Here is a list of advantages associated with hot water circulating pumps: Now lets have a look at the disadvantages of these pumps: Needless to say, recirculation pumps are not free. Some brands/models dont include it. (+ Calculator), 5 Best Air Purifiers For Allergies In 2023 (+ H13 Medical-Grade HEPA Filters), Is A Tankless Water Heater Worth It? Press J to jump to the feed. I bought the remote PB you referenced above and the specs on it say it uses 12 VDC, but I couldn't find anywhere whether the 12 V supplied by the Navien board is either AC or DC. NAVIEN NPE-180A SERVICE MANUAL Pdf Download | ManualsLib but you stopped short for me. Im interested in information on a tankless water heater with a built in recirculating pump. Way too many variables to even begin to diagnose online IMO. To install a full recirculating pump system, you need to consult with a plumber because you will need an extra pipe. To create an energy-efficient full recirculation system, your pump has to come with these two efficiency optimizing parts. I guess the recirculation line will be the only one that is copper. Difficulties with estimation of epsilon-delta limit proof. Yes, you can turn off your hot water recirculating pump. Turn off the device for 30 minutes and then restart it. Crazy coincidence that I ran into your post because I've been researching the same issue. It sounds almost like cavitation or a magnet rubbing against the casing as the recirculating pump winds down. Any tips on where to verify if I have a dedicated return line? But, making sure youre doing it the right way is important. 2. I have a clog, When the faucet is on the unit is indicating flow rate of 1.4 GPM which seems plenty and the recirculation mode is set to external & always on. Another suggestion I can give you is to maintain and service your Navien water heater according to the manual. You can adjust the temperature by the below 10-degree increments, depending on the temperature range: 98 F-120 F/ 36 C-50 C 1 F or 0.5 C increments, 120 F-140 F /50 C-60 C Press for 2 seconds to adjust in 5 F or 2C increments. The only problem you have is there is no check valves in place check valves or like stop signs that direct traffic check valves, direct to flow of water. air). Separate Recirculation Pumps. Video of the Day Step 2 Check the three wires are connected to the plug terminals. Signs There's a Problem with Your Hot Water Recirculating Pump - Maeser The heating supply thermistor is defective. It has a timer that turns on the pump at regular intervals, mostly during peak usage times. If water comes out from the pressure relief pipe, this indicates that the issue is not with the unit but with the house's plumbing. Then, turn it on again. The error code E441 informs about the open thermistor or short circuit problem. What is more, you can, by these estimates, reduce the future water bill considerably and actually profit nicely just by not needlessly waiting for water when youre waiting for the hot water to kick in. To remedy this, you can take the two clamps off the sensor, pull it out and clean it. Now, you have to know the hows for reducing damage. How can this new ban on drag possibly be considered constitutional? Navien NPE-240s with external recirculating pump. Also, check the filters to see if they are clean. Now, we have to check if these costs are balanced out by the water savings. To select a recirculation mode, you must set the DIP switches on the front panel, and set the position of the 2-way valve inside the water heater. In compliance with California's . You just have to set the timer as you use it. Navien NPE-240 A Recirculation Line www.amazon.com/shop/miheatingguy Milwaukee 2131-20 M18 ROCKET Dual Power Tower Light Hot Water Recirculating Loop Owen Perkins 81K views 3 years ago NAVIEN. As an Amazon Associate we earn from qualifying purchases. It means there is some issue with the OT-remote controllers operation. When attempting a flush of the system, I shut off the hot and cold valves that lead into the heater. Do the plumbers explanations make any sense at all or does it sound like BS? Controling Navien NPE internal recirculation pump You can crack open the manual for your tankless heater and check if it comes with that option. I mounted the contact switch inside the cabinet per the kit instructions. $197.08 $ 197. Troubleshooting Navien NPE-240A Internal Recirculation Pump This is done every time you close the faucet. This on-demand water heater has a lower carbon footprint, is energy efficient, and has a longer lifespan. Air in the line: If there has been a power outage or air has gotten into the line for another reason, the pump can make a lot of noise. For example, you may damp it into a bathtub, pushing the water through the isolation side on hot. Side question: are you able to explain to me what always on means? Just like everything with these three characteristics, it is time-consuming and challenging. Does It Save Money? Save my name, email, and website in this browser for the next time I comment. This depends on how long you leave it on and how often you use it. Thanks for confirming and letting me know about the potential damage to the circulating pump as that hadn't occurred to me. Now you have your socket, turn it off/on whenever you want! You will see in the photo that the cold water valve shuts off water into the domestic water inlet but doesn't have a shut off into the circulation water inlet. The user manual for these devices (of which I own two) provides a pretty good plumbing diagram for proper install. I bought the. Some pumps, in order to avoid needing a dedicated return path, will recirculate the water via the cold water supply, so getting some hot water from the cold supply would be normal in this case. Prevention of Modern Slavery Progress Reports. I am guessing that he only returned the HOT line, hence the delayed time in "INSTANT HOT", as the Naviens are sold as well as there 96% efficiency!! Watt recirculating pump installed on the water heater (pump plugged into standard 110/120V outlet, 3/4-inch pipe thread connectors, valve). If we dont use it, we waste a lot of water. Tankless Water Heater Breaker Size Calculator: What Size Breaker? Lets outline them here: To determine if installing a hot water recirculation pump makes sense for your situation, we have to check the pros and cons. If necessary, replace them all. Close the isolation valves to the cold-supply and recirculation lines. I noticed my apartment building installed one and at that time the whole water pressure was low. Examine and clean the filter in a cold water inlet. Do you want to know the details? Follow Up: struct sockaddr storage initialization by network format-string, Bulk update symbol size units from mm to map units in rule-based symbology, Short story taking place on a toroidal planet or moon involving flying. These are the kinds of issues that can occur if you aren't aware of the automatic appliances that are connected to your system (and don't shut them off along with the water). To remedy this issue, turn off the heater for some time and restart it. Average 1-6 Person Home kWh Usage, Gas Vs Electric Water Heater Monthly Cost Comparison (State-By-State), Water Heating Costs For 1,2,3,4,5,6 Family Homes (State-By-State Analysis), Electric Water Heating Cost, kWh Usage Per Month (State-By-State RECS Analysis), What Is W2 Wire On Thermostat? Those are quite significant savings. This setup is very similar to the one I have with my 40 gallon tank setup with recirc/return line by using an X10 home automation module to program the remote to turn the pump on for 4 minutes and automatically turn off whenever someone presses it before taking a shower. Now, that comes to the question, can I turn off my hot water recirculating pump? When I hooked hoses to the service pipes, the system still produced a strong, steady flow of water, seeming to not drain. Is the plumbers reasoning valid here? It's unfortunate he's not around to explain all this to you. Find applications from Grundfos related to this subject. Recirculation Settings by pressing down the OK button. Note on tankless hot water heater recirculation pumps (double trouble solved). Therefore, the total peak demand of hot water needed is the ideal size of the heater you should get. Yes, you can turn off your hot water recirculating pump. The DIP switch setting has some problems. Consider yourself lucky if this installation hasn't damaged your circulating pump inside the unit. Legal Disclosure:Lildutchuncle.com provides and shares information on plumbing, heating & air quality, home improvement, and other DIY projects. (1000-3000+ Sq Ft Homes), Thermostat Says Heat On But No Heat? We don't tend to provide any plumbing advice or any advice that should come from a certified professional. Navien's patented ComfortFlow system is the first to include a buffer tank, recirculation pump and fine-tuned controls into a tankless water heater, resolving the cold-water sandwich effect* and issues of minimal flow rates commonly found in other tankless water heaters. You can return the item for any reason in new and unused condition: no shipping charges ; If you've got a tankless water heater installed that doesn't come with a built-in recirculation pump, then in such a scenario, a separate recirculation pump can do the trick for you. Here are four problems with these pump systems that you should be aware of. The best answers are voted up and rise to the top, Not the answer you're looking for? He obtained his Bachelor of Science degree from the University Of Texas at El Paso. Unscrew the plug cover with a suitable screwdriver to remove it. Get a sump pump and connect the cold service hose to the sump pump. Also, check the feeder valve and pressure relief valves activity. Make sure the electrical cord is grounded. But in my case its significant amount of time and it only really gets hot if I fully open the hot water at that faucet otherwise it is luke warm. If pointed in the right direction, though, I might be able to solve this. It is located on the lowest corner opposite the on and off button. 14 Culprits To Check For Now, MMBTU To MMSCFD Calculator For Natural Gas + Chart, 8 Best Infrared Heaters For Indoors, Patios, Garages (With ECO Thermostats), AGM Battery Voltage Charts: 12V, 24V Deep Cycle Battery Voltage, Lead-Acid Battery Voltage Chart For 6V, 12V, 24V, 48V Batteries, Natural Gas MMSCFD To MMBTU/Day Calculator + Chart. Navien has an aftermarket add on hot point or something that lets you control when the recirc is on.